Water to Air Geothermal Heat Pump – From The “Q”

The “Q” in Q Energy Systems represents “The HEAT added to the system”. Q Energy Systems Geothermal Heat Pumps also provide for cooling as well. Our all aluminum cabinet not only provides corrosion resistance, but also is a major contributor to how quiet the Q operates in your home. Our sound levels (decibel rating) is one of the lowest in the industry. Our Marine grade, anti-bacterial insulation assists with the sound attenuation, but is more importantly a safe, bio resistant insulation. We have strategically place the insulation in our equipment to ensure the Q is one of the Quietest Geothermal Heat Pumps.

Our Q Energy Control System is state of the art technology. Our control is Wi-Fi compatible, yes, you can control and monitor your system from anywhere in the world. All you need is an internet connection. Smart Phone, Tablet or PC, have one of those and you are set. Just need to you setup the online portal.

Download Product Brochure PDF - A5 Water-to-Air

Download Product Brochure PDF - A7 Water-to-Air

Our cabinet panels are fully removable and utilize a “quarter turn fastener” that leaves the fastener secure into the panel. Our design affords easy access to the major components of our equipment. The TXV, blower ECM module, liquid line drier, reversing valve, desuperheater system, and all other components have been placed for easy diagnostics, access and maintenance. In the unlikely event that a component requires replacement our design will cut replacement time in half.

We designed a 4” Filter rack for a couple of reasons, first there is more surface area for greater filter efficiency and secondly, because of this increase in surface area it lowers the static pressure drop through the filter.

We have incorporated the Nidec/US Motors (formerly Emerson) Selectech blower in our equipment. This blower uses 5 x 24v speed taps versus 230v speed taps. Hi voltage can produce EMF and affect the operation of the control system. For this reason alone we chose the Selectech Blower. It comes fully programmed with the correct torque and CFM settings for the tonnage of equipment.

Our internal plenum design is unique. It provides a direct connection to the blower housing, it also provides for proper airflow right from the start-up of the system. You just connect to a properly designed and installed duct system and a way you go. Oh and one more thing, Q Energy Packaged systems comes with the supplemental Electric Heater installed and wired to our Q control, you just tell us what your design requires and it is built in. It’s that simple.

We offer the Q Energy Packaged system in sizes from 2 thru 6 Ton. We offer Q Energy Packaged systems in Left or Right Return configuration. Of course, configuration must be specified when ordering.

To learn more about the Q and learn how affordable Geothermal is, contact one of our experienced Q Contractors in your area. Just go to the Q Contractor locator and enter your zip. Q contractors are the best in the business at what they do. Q Contractors have the experience and technical expertise that you except from a professional geothermal contractor.

  • All aluminum, corrosion resistant cabinet.
  • Marine grade, anti-bacterial, bio resistant insulation.
  • Insulation maximizes sound attenuation and moisture control.
  • State-of-the-art, Wi-Fi technology for controlling, monitoring and troubleshooting the system.
  • Cabinet design affords ease of access to the major components.
  • Cabinet panels are fully removable and utilize “quarter turn” fasteners.
  • Components have been placed for easy diagnostics, access and maintenance.
  • 4″ filter rack provides efficiency and lowers the static pressure drop.
  • Incorporated Selectech blower.
  • Unique internal plenum design is unique in the industry, and provides proper airflow.
  • Supplemental electric heater install and wired to our “Q” Control System.
  • Available in sizes from 2 through 6 ton, and left or right return configuration.

2-Ton Water to Water – Performance Data Summary (full load)
Ground Water (open) Ground Loop (closed)
Cooling Heating Cooling Heating
Capacity EER Capacity EER Capacity EER Capacity EER
26,771 21.00 28,614 3.60 25,025 16.50 25,684 3.40
3-Ton Water to Water – Performance Data Summary (full load)
Ground Water (open) Ground Loop (closed)
Cooling Heating Cooling Heating
Capacity EER Capacity EER Capacity EER Capacity EER
29,620 20.70 30,604 3.90 27,475 16.80 27,323 3.30
4-Ton Water to Water – Performance Data Summary (full load)
Ground Water (open) Ground Loop (closed)
Cooling Heating Cooling Heating
Capacity EER Capacity EER Capacity EER Capacity EER
48,426 20.50 45,801 3.90 44,346 16.50 36,843 3.20
5-Ton Water to Water – Performance Data Summary (full load)
Ground Water (open) Ground Loop (closed)
Cooling Heating Cooling Heating
Capacity EER Capacity EER Capacity EER Capacity EER
57,686 20.30 62,452 3.80 54,107 16.30 55,703 3.20
6-Ton Water to Water – Performance Data Summary (full load)
Ground Water (open) Ground Loop (closed)
Cooling Heating Cooling Heating
Capacity EER Capacity EER Capacity EER Capacity EER
63,596 20.20 65,934 3.70 59,316 16.30 58,386 3.10